Title
A holistic approach for the detection of media-adventitia border in IVUS.
Abstract
In this paper we present a methodology for the automatic detection of media-adventitia border (MAb) in Intravascular Ultrasound. A robust computation of the MAb is achieved through a holistic approach where the position of the MAb with respect to other tissues of the vessel is used. A learned quality measure assures that the resulting MAb is optimal with respect to all other tissues. The mean distance error computed through a set of 140 images is 0.2164 (+/- 0.1326) mm.
Year
DOI
Venue
2011
10.1007/978-3-642-23626-6_51
MICCAI (3)
Keywords
Field
DocType
robust computation,mean distance error,media-adventitia border,automatic detection,holistic approach,quality measure,intravascular ultrasound
Computer vision,Intravascular ultrasound,Computer science,External elastic lamina,Artificial intelligence,Adventitia,Computation
Conference
Volume
Issue
ISSN
14
Pt 3
0302-9743
Citations 
PageRank 
References 
3
0.45
11
Authors
6
Name
Order
Citations
PageRank
Ciompi Francesco183739.53
Oriol Pujol296360.82
C. Gatta352137.03
Xavier Carillo4686.92
Josepa Mauri512312.15
Petia Radeva61684153.53